This error occurs, if your CodeMeter Runtime installation still contains some old components. Please check, if the file 'C:\Program Files (x86)\CodeMeter\Runtime\bin\WibuCm32.dll' is still on your sys meer
The error 106 refers to an "invalid handle" and occurs if a handle was used CodeMeter does not know. This may, for instance, happen in the following cases: 1. You use a protected software or a softwar meer
Error 231 occurs when trying to assign a license to a CodeMeter License Server whose license access permissions exclude the client. Please open CodeMeter Control Center on the server and use the WebAd meer
If the error 229 occurs. the problem does not involve the license update file (*.WibuCmRaU) but the license request file (*.WibuCmRaC) as basis for programming the update. Exactly from this context fi meer
to reset the local access to the WebAdmin, proceed as follows, depending on the operating system: Windows 1. Open a prompt window ([Win]+[R] input 'cmd') 2. Navigate via 'cd' to C:\Program Files (x86) meer
To switch CodeMeter WebAdmin to HTTPS on a Linux system and enable write protection, please proceed as follows: 1) Set the desired password for CodeMeter WebAdmins write access using the following "cm meer
With the changes of CodeMeter WebAdmin in version 6.90 the configuration has changed, which is required to make CodeMeter WebAdmin "visible" in the network, i.e. readable remotely. The new service CmW meer
To check, if the if CodeMeter WebAdmin is running on your Linux system, please proceed as follows: 1. Open a terminal window. 2. Type command: sudo service codemeter-webadmin status The deamon script meer
If the CmDongle is not recognized as a device by Linux-Embedded, the CmDongle must be mounted with increased rights. For HID-Dongles (Human Interface Device) enter the command: sudo chmod o+rw /dev/hi meer
If those errors display, errors in the USB communication with the CmDongle have been occurred. If the communication after several attempts still fails, finally Error 70 displays and no further communi meer
Please send damaged CmDongles to the address stated below. Please also enclose a note, if a special defect exists, e.g. information on related Ticket ID: WIBU-SYSTEMS AG - COMPLAINT - Zimmerstraße 5 D meer
Causes: The fact that the Firm Access Counter (FAC) has a value of 0 can have various causes: 1. First, the FAC may have been set to a value of 0 by a protected application. This reduction is a securi meer
If a CmDongle is connected and can be displayed and read in CodeMeter Control Center, it can usually be assumed that it is working. A defect of a CmDongle is already apparent when connecting. In CodeM meer
Which mode is to be used can be set via the Windows registry and the UseUmsDA key. Proceed as follows to open the registry: - Press the key combination [Windows] + [R] to open the dialog "Execute". - meer
For older CmDongles with a specific controller version, there is no firmware version 2.x, because these controllers do not possess sufficient memory for the changed firmware update procedure that was meer
Depending on the BIOS and the configuration of the boot manager of your system, it might occur that your system hangs during boot procedure. This happens because the system tries to boot from the CmDo meer
In earlier firmware versions it could happen that the certificates within a Firm Item were no longer correctly available due to a very rare error. In this case, no Context File of this Firm Item could meer
You can reset the CodeMeter password for your CmDongle using the CodeMeter Master Password of this CmDongle. Please proceed as follows: - Open CodeMeter Control Center. - Select the desired CmDongle o meer
Please send an e-mail to support(at)wibu.com. If you have a license request file (*.WibuRaC) you previously created via CodeMeter Control Center, attach it to the mail. Alternatively, you can also att meer
There are two ways to perform an online firmware update. Either you use CodeMeter Control Center or the CodeMeter command line utility cmu. CodeMeter Control Center - Open CodeMeter Control Center. - meer