CodeMeter WebAdmin exists since CodeMeter v6.60 as an independent 32-bit and 64-bit Windows service (CmWebAdmin). On a 64-bit system, the 32-bit variant is not installed, only the 64-bit variant is in more
CmDongles without real flash memory, i.e. devices with a memory of less than 128 MB, can be configured to be detected as a local disk or removable disk. Depending on how your system is configured and more
Please register your CmDongle at my.codemeter.com and request the Master Password for your CmDongle by specifying the serial number with an email to support(at)wibu.com. You will receive the CmDongle more
Creating a CD-ROM partition and writing a *.iso file for a CmStick with flash memory involves the following 5 steps: Step 1. configure enabling blocks to control the CD-ROM partition. Step 2. create t more
Please send damaged CmDongles to the address stated below. Please also enclose a note, if a special defect exists, e.g. information on related Ticket ID: WIBU-SYSTEMS AG - COMPLAINT - Zimmerstraße 5 D more
Causes: The fact that the Firm Access Counter (FAC) has a value of 0 can have various causes: 1. First, the FAC may have been set to a value of 0 by a protected application. This reduction is a securi more
If a CmDongle is connected and can be displayed and read in CodeMeter Control Center, it can usually be assumed that it is working. A defect of a CmDongle is already apparent when connecting. In CodeM more
Which mode is to be used can be set via the Windows registry and the UseUmsDA key. Proceed as follows to open the registry: - Press the key combination [Windows] + [R] to open the dialog "Execute". - more
In such a case, it may help to give CodeMeter full disk access. To do this, please proceed as follows: 1. Open System Preferences. 2. Navigate to System Preferences Security & Privacy more
EBL stands for "ExecuteBciLow". And Bci for "Basic Command Interface". Here corresponding commands are sent to the CmDongle and then evaluated or processed there. Accordingly, errors can also occur, w more
If the CmDongle is not recognized as a device by Linux-Embedded, the CmDongle must be mounted with increased rights. For HID-Dongles (Human Interface Device) enter the command: sudo chmod o+rw /dev/hi more
If those errors display, errors in the USB communication with the CmDongle have been occurred. If the communication after several attempts still fails, finally Error 70 displays and no further communi more
The flashing represents mainly an information for our hardware department to gain further information in special cases. As a rule, the LED of the CmDongle flashes during read or write accesses and can more
In earlier firmware versions it could happen that the certificates within a Firm Item were no longer correctly available due to a very rare error. In this case, no Context File of this Firm Item could more
You can reset the CodeMeter password for your CmDongle using the CodeMeter Master Password of this CmDongle. Please proceed as follows: - Open CodeMeter Control Center. - Select the desired CmDongle o more
Depending on the type, CmDongles support different communication types (USB device classes): Human Interface Device (HID) and Mass Storage Device (MSD). In the case of HID, a connected CmDongle behave more
To run the CmStick BMC under current Debian-based / Red Hat Enterprise Linux distributions, the CodeMeterLin Deamon must be started as 'root'. Proceed as follows: 1. Execute the following command in t more
Starting with Version 5.0, CodeMeter supports devices that conform to the USB Human Interface Device (HID) class specification. As an alternative option to the Mass Storage Device status, CmDongles ca more
For older CmDongles with a specific controller version, there is no firmware version 2.x, because these controllers do not possess sufficient memory for the changed firmware update procedure that was more
Depending on the BIOS and the configuration of the boot manager of your system, it might occur that your system hangs during boot procedure. This happens because the system tries to boot from the CmDo more
Questa schermata riduce il consumo di energia del monitor quando non sei attivo sul nostro sito. Per riprendere la navigazione è sufficiente muovere il mouse.