to reset the local access to the WebAdmin, proceed as follows, depending on the operating system: Windows 1. Open a prompt window ([Win]+[R] input 'cmd') 2. Navigate via 'cd' to C:\Program Files (x86) more
To switch CodeMeter WebAdmin to HTTPS on a Linux system and enable write protection, please proceed as follows: 1) Set the desired password for CodeMeter WebAdmins write access using the following "cm more
With the changes of CodeMeter WebAdmin in version 6.90 the configuration has changed, which is required to make CodeMeter WebAdmin "visible" in the network, i.e. readable remotely. The new service CmW more
If those errors display, errors in the USB communication with the CmDongle have been occurred. If the communication after several attempts still fails, finally Error 70 displays and no further communi more
Please send damaged CmDongles to the address stated below. Please also enclose a note, if a special defect exists, e.g. information on related Ticket ID: WIBU-SYSTEMS AG - COMPLAINT - Zimmerstraße 5 D more
Causes: The fact that the Firm Access Counter (FAC) has a value of 0 can have various causes: 1. First, the FAC may have been set to a value of 0 by a protected application. This reduction is a securi more
If a CmDongle is connected and can be displayed and read in CodeMeter Control Center, it can usually be assumed that it is working. A defect of a CmDongle is already apparent when connecting. In CodeM more
The flashing represents mainly an information for our hardware department to gain further information in special cases. As a rule, the LED of the CmDongle flashes during read or write accesses and can more
In earlier firmware versions it could happen that the certificates within a Firm Item were no longer correctly available due to a very rare error. In this case, no Context File of this Firm Item could more
You can reset the CodeMeter password for your CmDongle using the CodeMeter Master Password of this CmDongle. Please proceed as follows: - Open CodeMeter Control Center. - Select the desired CmDongle o more
In such a case, it may help to give CodeMeter full disk access. To do this, please proceed as follows: 1. Open System Preferences. 2. Navigate to System Preferences Security & Privacy more
EBL stands for "ExecuteBciLow". And Bci for "Basic Command Interface". Here corresponding commands are sent to the CmDongle and then evaluated or processed there. Accordingly, errors can also occur, w more
If the CmDongle is not recognized as a device by Linux-Embedded, the CmDongle must be mounted with increased rights. For HID-Dongles (Human Interface Device) enter the command: sudo chmod o+rw /dev/hi more
Which mode is to be used can be set via the Windows registry and the UseUmsDA key. Proceed as follows to open the registry: - Press the key combination [Windows] + [R] to open the dialog "Execute". - more
For older CmDongles with a specific controller version, there is no firmware version 2.x, because these controllers do not possess sufficient memory for the changed firmware update procedure that was more
Depending on the BIOS and the configuration of the boot manager of your system, it might occur that your system hangs during boot procedure. This happens because the system tries to boot from the CmDo more
To check, if the if CodeMeter WebAdmin is running on your Linux system, please proceed as follows: 1. Open a terminal window. 2. Type command: sudo service codemeter-webadmin status The deamon script more
CodeMeter WebAdmin is based on HTML code including Javascript. The full functionality requires the activation of Javascript, e.g. on selecting a single CmContainer when several CmContainer are used. W more
This might have several reasons. Please proceed as follows: 1. Check whether the browser is in "offline mode". If this is the case, please switch the mode. In the Internet Explorer, for example, deact more